<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Mambodyssee &#187; OptiSonde</title>
	<atom:link href="http://www.mambodyssee.com/tag/optisonde/feed" rel="self" type="application/rss+xml" />
	<link>http://www.mambodyssee.com</link>
	<description>Autos, Entertainment, Travel</description>
	<lastBuildDate>Thu, 26 Aug 2010 14:43:35 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.5</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>OptiSonde Chilled Mirror Hygrometer &#8211; GE Sensing</title>
		<link>http://www.mambodyssee.com/39/optisonde-chilled-mirror-hygrometer-ge-sensing.html</link>
		<comments>http://www.mambodyssee.com/39/optisonde-chilled-mirror-hygrometer-ge-sensing.html#comments</comments>
		<pubDate>Tue, 27 Nov 2007 09:07:50 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Auto]]></category>
		<category><![CDATA[Chilled]]></category>
		<category><![CDATA[GE Sensing]]></category>
		<category><![CDATA[Hygrometer]]></category>
		<category><![CDATA[Mirror]]></category>
		<category><![CDATA[OptiSonde]]></category>

		<guid isPermaLink="false">http://www.mambodyssee.com/39/optisonde-chilled-mirror-hygrometer-ge-sensing.html</guid>
		<description><![CDATA[GE Sensing announces the OptiSonde        humidity indicator, transmitter and data logger. The OptiSonde is the        first chilled mirror hygrometer to offer the precision and repeatability        previously found only in laboratory standards, to a compact [...]]]></description>
			<content:encoded><![CDATA[<p><!--adsense--><strong>GE Sensing</strong> announces the <strong>OptiSonde<span id="bwanpa3"></span>        humidity indicator, transmitter and data logger</strong>. The <strong>OptiSonde</strong> is the        first <strong>chilled mirror hygrometer</strong> to offer the precision and repeatability        previously found only in laboratory standards, to a compact and        economical instrument suitable for industrial applications.<span id="more-39"></span>       The <strong>OptiSonde</strong> may be used to calibrate and verify a wide variety of        humidity sensors and instruments. It is ideally suited for documenting        the environmental conditions of process and storage areas. The <strong>OptiSonde</strong>        utilizes technology of choice for monitoring humidity and temperature in        pharmaceutical process, environmental test chambers, automotive and        aerospace engine emissions and testing, heat exchanger and air        conditioning performance testing applications.</p>
<p>Incorporating a rugged, compact design, the <strong>OptiSonde</strong> is a true 1%RH        <strong>hygrometer</strong> equipped, which facilitates recordings of test environments,        with an internal data logger.</p>
<p>The <strong>OptiSonde</strong> directly measures dew point temperature by using an        infrared light emitter and detector to regulate heat being removed from        a precious metal mirror, regulating a condensed dew or frost layer to a        constant mass. The temperature of the mirror is measured by a precision        resistance temperature detector. When the mass of the condensed water is        at equilibrium, the temperature of the mirror is, by definition, equal        to the dew point temperature. By simultaneously measuring the ambient        temperature humidity parameters, relative humidity, absolute humidity,        volume and mass ratios are calculated by the <strong>OptiSonde</strong> with high        precision.</p>
<p>The analyzer is available in bench-top and wall mounted configurations.        For room monitoring, the chilled mirror and temperature sensor is        plugged directly onto the chassis, or the sensors can be installed up to        300 ft (100 m) away and connected via cable. The <strong>OptiSonde</strong> indicates two        user selected parameters simultaneously as well as system status and        diagnostics. In addition to the LCD readout, data is transmitted via two        fully scaleable analog signals (4-20mA) and digitally via an RS-232        port. The unit is equipped with a data logger that enables long-term        data to be saved. The OptiSonde is supplied with PanaView software to        enable data uploading to a PC for graphing and data reduction. The data        may also be exported as an ASCII text file format for use in        spreadsheets. The <strong>OptiSonde</strong> incorporates GE Sensing<span id="bwanpa4">’</span>s        patented PACER cycle which is an automatic means of self-cleaning and        balancing the sensor optics.</p>